  "scope": "NGSPICE_DC_GENERIC_MOS_ENGINEERING_MODEL_ONLY",
  "corners": 256,
  "all_checks_pass": true,
  "ce_disabled_min_v": 4.293529967526892,
  "ce_enabled_max_v": 0.005205279507852536,
  "supervisor_clamp_max_sink_a": 0.00048589898989898983,
  "vendor_tps3808_model_used": false,
  "vendor_tlv7044_model_used": false,
  "vendor_bq24074_model_used": false,
  "vendor_ao3400a_model_used": false,
  "transient_simulation": false,
  "physical": "NOT_RUN",
  "assumptions": [
    "Generic LEVEL1 NMOS VTO0.65..1.45V and KP0.5..1 are engineering parameters, not a measured/vendor AO3400A fit; subthreshold leakage omitted",
    "HC14 output represented by ideal voltage source 0/3.84/5.25V; TPS asserted RESET represented by ideal 0.4V clamp; no POR, dynamic logic, thermal or turn-off timing modeled",
    "R20 +/-1%, existing 4755 pulldown assumed +/-5%, gate resistor +/-1%",
    "No battery, charger power path or actual charge-current simulation",
    "DC CE and clamp current budgets alone cannot release automatic charging"
  ]
}