Dry-cabinet manufacturers
Integrate humidity measurement, door inputs, dehumidifier control and service records in one controller architecture.
CAB120 · DRY CABINET CONTROL
A controller architecture for low-humidity electronics storage. Combine dual-probe measurement, dehumidifier requests, door-event recording, independent interlock logic and service data export. Explore the electronics, firmware, cabinet CAD and complete technical files.

Integrate humidity measurement, door inputs, dehumidifier control and service records in one controller architecture.
Manage storage monitoring for moisture-sensitive components, PCB assemblies and production materials.
Use editable electronics, firmware, wiring and cabinet CAD as the basis for cabinet customization.
Two Vaisala HMP7 probes connect through isolated RS485. Temperature and humidity data feed the control and logging functions.
ESP32-S3 handles settings, control requests, door events, local records and maintenance export.
ILIO24 and the active carrier condition control inputs and provide an enable latch and status interfaces.
MON01 monitors the supply domains and provides voltage-window and power-good signals.
An external DST RECUSORB DR-010B connects through the isolated control interface.
STEP, DXF, mounting details, cable routes, terminal tables and the system BOM link electronics to the cabinet assembly.
| Board | Key devices | Role |
|---|---|---|
| DCAB v0.20 | ESP32-S3 | Dual probe acquisition, control requests, event records and export |
| ILIO24 R03 | TPS79850 / TPS3700 / SN74LVC3G17 | Field-supply conditioning and interlock logic |
| ILDOCK R03 | SN74LVC1G74 | Active carrier and enable latch |
| MON01 R02 | TPS3700 / TPS3808 | Supply-window monitoring and power-good signals |
Dual HMP7 / isolated RS485 / temperature and humidity records. Probe connection and signal mapping are included in the hardware files.
Door events, dehumidification requests, damper-position inputs and interlock status are mapped in the point-to-point wiring table.
microSD records, RTC timestamps, USB Serial/JTAG maintenance and CSV export verification tools.
The main application uses the 0.15-dst profile. The interlock application uses 0.3-hw-latch. Each source package includes its pin mapping, build configuration, application images and associated technical records.
Open each image for a larger view. Editable board layouts and component data are included in the corresponding KiCad package.
Cabinet CAD R06 brings the board mounting, supports, cable paths and fastener geometry together. The R22 system BOM, R12 wiring and R06 terminal table provide a consistent material and connection index. The cabinet package includes the associated selection correction document.
Cabinet assembly, mounting plates, support geometry and hole projections.
System materials, PCB sub-BOMs, point-to-point wiring and terminal assignments.
Fastener stacks, tooling references, cable-end details and the terminal assembly guide.
Download the complete collection, or choose the hardware, firmware, cabinet and wiring files you need. Native sources and their original technical records are preserved in each package.
Share the cabinet volume, humidity target, probe arrangement, dehumidifier interface and data-export requirements to define your controller and PCBA scope.